Features:
Advanced optical design, convergent Fu Liye transform test technique
Superior automatic centering system and computer operating system
High stable light path optimization, unique dry dispersion system
Computer controlled feeding, accurately control the feed quantity
Dust proof, shock proof design, unique suspension structure
Technical Parameters:
Model | MPSA-2000L | |
Execution Standard | ISO 13320-1:1999;GB/T19077.1-2008 | |
Test Range | 0.1μm -800μm | |
Detector Channel Number | 76 | |
Accuracy Error | <1%(national standard sample D50 value) | |
Repeatability Error | <1%(national standard sample D50 value) | |
Feeding Method | Mechanical stepless speed regulation feeding, software control | |
Oil-free Silent Air Compressor | With dust filter function to ensure the accuracy of the test | |
Cold Dryer | Freeze dryer can filter the moisture in the air to ensure the dispersion effect | |
Mis Operation Protection | The instrument has the function of self-protection by mistake operation | |
Laser Parameters | Imported optical fiber output high power laser lambda = 650nm, p>10mW | |
Dispersion Method | High pressure air dispersion | |
Operation Mode | Software automatic control operation | |
Optical Alignment | Optical path automatic proofreading | |
SoftwareFunction | Analysis Model | Including free distribution, R-R distribution and log normal distribution, according to the hierarchical statistical model and so on, to meet the requirements of different industries on the size of the sample under different statistical methods |
Statistical Method | Volume distribution and quantity distribution in order to meet the different statistical methods of particle size distribution in different industries | |
Statistical Comparison | For a number of test results were compared and analyzed, the difference was compared before and after the processing of different batches of samples, sample time and different test results, has great practical significance for the quality control of industrial raw materials | |
Self DIY Display Template | User defined data to be displayed, according to the percentage of particle size, according to the percentage of particle size oraccording to the percentage of particle size range, in order tomeet the different industries on the characterization of particlesize test. Distance, consistency, interval accumulation, etc. | |
Test Report | Test reports can be exported to Word, Excel, Bmp (picture) and text(Text) and other forms of documentation, to meet the test reportin any situation and test results cited in scientific researcharticles | |
Multi LanguageSupport | Chinese and English language interface support, but also accordingto user requirements embedded in other language interface. | |
Intelligent OperationMode | Fully automatic unattended operation, no one is a factor ofinterference, you simply press the tip to join the sample to betested, the test results are better repeatability. | |
Test Speed | <1min/ times (excluding sample dispersion time) | |
Power Supply | AC 220V±10% 50Hz | |
Power Consumption | 2500W | |
External Size(W*D*H) mm | 980*410*450 | |
Packing Size(W*D*H) mm | Mainframe:1040*410*540 710*540*540Attachment: 340*340*700*3pcs | |
G.W.(kg) | 120 |
Copyrights © Medfuture Biotech Co., Ltd. All Rights Reserved